Ecosoft MO24 industrial reverse osmosis system is a turnkey solution for industrial water challenges, that includes pilot studies, engineering and manufacturing, commissioning and maintenance.
Ecosoft reverse osmosis systems are used in food and pharmaceutical industry, energy, chemical, semiconductor manufacturing, steam boilers and other industrial applications.
Permeate capacity
24–28
m³/h
Recovery
75
%
Maximum TDS
3000
mg/L
Influent flow demand (service)
30–40
m³/h
Operating pressure
8..12
bar
Power consumption
18.5
kW
Equipment
- Grundfos® CR 45-4 high pressure pump: 1 pcs
- 8040-4 membrane vessel: 6 pcs
- Stainless steel housing with 7 PP 2,5 × 40″ filters: 2 pcs
- Motorized butterfly valves (feed water in, flush out): 2 pcs
- Balancing valves (concentrate reject, concentrate recycle): 2 pcs
- Electrical cabinet with Ecosoft controller: 1 set
- Piping, instrumentation: 1 set
- Steel frame: 1 set
Options
- Filmtec™ XLE-440 / ECO PRO-440 or Ecosoft ELP-8040 membranes
- Dosing pump for antiscalant or other RO chemicals
- Permeate inlet for permeate membrane rinse
- Raw water blending line
Сonnections
- Influent water: DN80
- Permeate: DN65
- Concentrate: DN80
Technical data
- Permeate capacity¹: 24 m³/h
- Permeate recovery²: 75%
- Maximum TDS: 3000 mg/L
- Influent flow demand: 30…40 m³/h (service)
- Operating pressure: 8…12 bar
- Maximum pressure: 14 bar
- Electrical requirements: 380...400 V, 50 Hz (3 ph)
- Electrical power: 18.5 kW
- Prefilter rating: 5 μm
¹ depends on feed water TDS, temperature, and permeate recovery
² for low scaling/fouling water
Feed water requirements
- TDS: 3000 mg/L
- hardness: 150 mg/L CaCO₃
- iron: 0.1 mg/L
- manganese: 0.05 mg/L
- hydrogen sulfide: none
- silicate: 20 mg/L
- residual chlorine: 0.1 mg/L
- SDI: 5
- chemical oxygen demand: 4 mg/L O₂
Product
Box
Image Size
DIMENSIONS, H×W×D:
1850 × 5287 × 1744
mm
Filter weight
1100
kg
Image Box
Dimensions, H×W×D:
1080 × 7500 × 2584
mm
Filter weight
kg