Operation

Operation of the dosing station presents accurate supply of small volumes of reagents from the tank into the water flow line with a dosing pump. The dosing pump sucks the solution out of the reagent tank, and delivers its certain volume to the system.

A filter is installed at the suction valve of the dosing pump to prevent sediments from entering the pump resulting in its clogging.

Technical parameters

  • Dosing mode: constant
  • Nominal back pressure (Pnom): 5 bar
  • Flow rate at Pnom: 0.8 L/h
  • Maximum back pressure (Pmax): 10 bar
  • Flow rate at Pmax: 0.6 L/h
  • Volume of one injection: 0.07 mL
  • Injection frequency: 0..120 injections/min
  • Noise level: 74 dBA
  • Dosing pump power: 16 W
  • Power supply: 230 V, 50 Hz
  • Temperature limit during storage / transportation: -10…+50 °С
  • Temperature of dosing solutions: 0...+50 °С
  • Material of components which contact with the dosing substance: EPDM
  • Reagents tank volume: 60 L
  • Reagents tank dimensions (diameter x height): 370 x 640 mm
  • Pump (H x W x D, mm): 155 x 95 x 125

Main components

  • Dosing pump
  • Suction valve with foot filter and level probe
  • Injection valve
  • Pack of hoses
  • Chemical tank with mounting bracket
  • 500 mL graduated cylinder
  • Water meter with pulse output (proportional dosing pumps only)

Benefits

 

  • Accuracy and ease of setting
  • Working pressure up to 10 bar
  • Flow rate up to 6 L/h
  • Low noise level
  • Graphic display and text menu
Industrial 8" Reverse Osmosis
EMEC FACO basic dosing pump set. 60 L
D100660
Ecosoft