Pre-configured and assembled systems with properly selected components. All you need to do is to add ECOMIX® or ion-exchange resin.
Set of equipment
CE TWIN 1.25" control valve 1
Pressure tank 21x62, 4" 2
Brine tank 3
1 CE TWIN 1.25" valve assembly (VTT1CEDME-03):
- CE TWIN 1.25" control valve
- Top stack distributor, 14 segments
- Connection kit 1.25''
- Power supply
- Injector, DLFC - for Ecomix and cation exchange resin
- Funnel
- Valve instruction manual, instruction manual
2 Pressure tank assembly
- Pressure tank 21x62, 4"
- Adaptor 4'' - 2.5''
- Riser DN 32 mm
- Bottom stack distributor, 15 segments
3 Brine tank assenbly
- Brine tank 24x50, 378 L
- Brine well assembly (brine valve, overflow set)
- Brine grid
Twin set may operate 2 units with alternativemode (the first unit in operation, the second -in regeneration or stand by) and can produce water during the day at constant flow rate.
CE CONTROL VALVE KEY FEATURES
- Regeneration control by water volume: delayed regen, immediate, both
- Possibility to change the cycle of regeneration stages and their range of time
- Multilanguage menu: English, German, French, Ukrainian
- Different setting modes are available:
- Twin or duplex configurations
- Up to 6 systems to the system controller
- 2 external devices simultaneously can be connected
SPECIFICATIONS
- Water flow rate*
- Service (pressure drop 1 bar): 6.12 m3/h
- Backwash (pressure drop 1.7 bar): 6.12 m3/h
- Inlet, outlet: G 1″
- Drine: G 1″
- Brine line: G 3/8″
- Operating pressure: 2-6 bar
- Operating temperature: +4...+30 oC
- Electrical requirements: 230 V, 50 Hz
- Electrical power: 30 W
* Only for Clack WS1.25 CE control valves includes meter, bypass, and 1.25" fitting kit
RECOMMENDED MEDIA VOLUME FOR ONE CYLINDER
- Ecomix Type C filter media: 150 L ***
- Ecomix Type A filter media: 150 L ***
- Ecomix Type P filter media: 150 L ***
- HCRS-S Strong acid cation exchange resin: 200...225 L
- PC002 Strong acid cation exchange resin: 200...225 L
The volume of filter material depends on the its characteristics. TDS on filter materials can be found on the official website www.ecosoft.com.
*** The amount of Ecomix can be increased by no more than 25 liters.