Replacement lamp T510 for Ecosoft UV HR-60 is intended for the ultraviolet water disinfection filter that provides epidemiological safety of water for drinking and household purposes at home, in hotels, bars and restaurants, water refilling stations and vending machines, and can be used as an integral stage in water purification plants and for various industrial processes.
Maximum disinfected water flow
0.23
m³/h
Type of lamp
T510
Max inlet pressure
8
bar
Electrical power of one emitter
10
W
Dimensions (L x D)
210 × 18
mm
Power supply
220 / 50
V / Hz
Performance
Replacement lamp T510 is mounted inside the body of the ultraviolet disinfection unit Ecosoft HR-60, where microorganism decontamination occurs.
Technical data
- Maximum disinfected water flow: 0.23 m³/h
- Type of lamp: T510
- Maximum inlet pressure: 8 bar
- Power supply: 230 V, 50 Hz
- Power consumption of one lamp: 10 W
- Appliance for lamp malfunction control: visual
- Dimensions (length x diameter): 210 × 18 mm
Feed water requirements
- Temperature of the treated water: +4...+30 °C
- Turbidity: 0.58 mg/L
- Total hardness: 125 ppm
- Iron: 0.3 ppm
- Manganese: 0.05 ppm
- Hydrogen sulfide: 0.05 ppm