SOFTENER HYGIENE GUARD
Designed for Ecomix softeners and softeners for chlorine disinfection systems from 12 to 200 liters media
Operation
Connect the probe to the softener salt line (use the necessary adapters). Check how many liters of resin are in your softener (look at your softener manual).
Disconnect the generator plug, open the generator (remove the screw above the box).
On the board, there is a trimmer (see the drawing). This trimmer can be set from 2 to 70 minutes. Every minute that you program can disinfect 1 L of resin.
Close the box, connect the plug. The system is ready to start.
How it functions:
During the softener rinse refill, the system checks if there's salt water. If there is, it applies electrolysis voltage to the probe for the time you set before. After this time, the generator stops for 4 hours. After these 4 hours, the system is ready again.
Components
- Electrical board
- Chlorine cell
- O-ring
- Connection wire
- Bolts
- Instruction manual
- Plastic box