FilmTec™ BW30HRLE-440 Membrane Element
Ideal for: reverse osmosis plant managers and operators dealing with controlled-pre-treatment waters and seeking advanced membrane treatment with good water purity and low energy consumption.
Typical Properties
- Active area: 41 m²
- Feed spacer thickness: 28 mil
- Permeate flow rate: 48 m3/d
- Typical Stabilized Salt: 99.3%
- Minimum Salt(ft Rejection: 99.1%
a. Permeate flow and salt (NaCl) rejection based on the following standard test conditions: 2,000 ppm NaCl, 150 psi (10.3 bar), 77°F (25°C), pH 8, 15% recovery.
b. Flow rates for individual elements may vary but will be no more than ± 15%.
c. Stabilized salt rejection is generally achieved within 24-48 hours of continuous use; depending upon feedwater characteristics and operating conditions.
d. Sales specifications may vary as design revisions take place.
e. Active area guaranteed ± 3%. Active area as stated by DuPont Water Solutions is not comparable to nominal membrane area often stated by some manufacturers.
Operating and Cleaning Limits
- Max. opearting temperature: 45 °С
- Max. opeartion pressure: 41 bar
- Max element pressure drop: 1.0 bar
- pH Range: 2-11
- Maximum Feed Silt Density Index: SDI 5
- Free Chlorine Tolerance: < 0.1 ppm
Customer Notice
DuPont strongly encourages its customers to review both their manufacturing processes and their applications of DuPont products from the standpoint of human health and environmental quality to ensure that DuPont products are not used in ways for which they are not intended or tested. DuPont personnel are available to answer your questions and to provide reasonable technical support. DuPont product literature, including safety datasheets, should be consulted prior to use of DuPont products. Current safety data sheets are available from DuPont.
Please be aware of the following:
- The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent on the complete system design and on the operation and maintenance of the system.
Regulatory Note
This product may be subject to drinking water application restrictions in some countries; please check the application status before use and sale.