Membrane elements EXLP 8040 are intended for purification of brackish water in low pressure systems.

Large active surface area together with high rejection rates allows to use these membranes in variable pressure and flow conditions without deterioration of permeate quality.

Permeate Flow Rate
48.4
m³/day
Active Membrane Area
37.2
Stabilized Salt Rejection
99.2
%
Operating pressure
6.9
bar

Specifications

Membrane type: spiral-wound element with polyamide thin-film composite

  • Active area: 37.2 m²
  • Operating pressure: 6.9 bar
  • Flow rate: 48.4 m³/day
  • Stabilized salt rejection: 99.2 %

* Permeate flow and salt (NaCl) rejection based on the following standard test conditions: 500 mg/L NaCl, 25 °C, permeate recovery asspecified below. Permeate flow rate for one element does not exceed ±20% of the nominal value.

Operating parameters

  • Maximum operating water temperature: 45 °C
  • Maximum operating pressure: 41 bar
  • Maximum element pressure drop: 1.0 bar
  • pH range, continuous operation: 3...10
  • pH range, short-term cleaning: 2...12
  • Maximum Feed Silt Density Index (SDI): 5
  • Free chlorine tolerance: < 0.1 mg/L

Product
Image Size
653f36e92dc9be24a5284a1d_photo_5332383425233014685_y.jpg
653f36e92dc9be24a5284a1d_photo_5332383425233014685_y.jpg
DIMENSIONS, H×W×D:
1016 (A) x 201 (B) x 29 (C)
mm
Filter weight
18
kg
ECOSOFT EXLP 8040 membrane element ➦ Quality is approved by the EAC. NSF and TÜV SÜD certificates. ✈ guarantee timely delivery of our products to any country of the world. ☑ 5 continents ☑ more than 60 countries ☑ Warehouses in 4 business areas (Western. Eastern Europe and the USA)
Industrial 8" Reverse Osmosis
Ecosoft EXLP-8040 8" membrane
EXLP8040
Ecosoft