Max flow rate
2.72
m³/h
Type and number of emitters
1 х T540
Max inlet pressure
8
bar
Electrical power of one emitter
40
W
Dimensions (L x W x H)
935 × 64 × 109
mm
Weight
4.3
kg
Operation
Water passes through the ultraviolet disinfectant, where the disinfection process takes place. The quartz cover is a necessary measure to prevent water from entering the case of the emitter.
UV disinfection unit maintenance
- Replace the lamp once a year.
- Clean components to remove mechanical impurities and plaque.
Technical data
- Maximum flow of disinfected water: 2.72 m³/h
- Type and number of emitters: 1 х T540
- Maximum inlet pressure: 8 bar
- Power supply: 230 V, 50 Hz
- Power consumption of one emitter: 40 W
- Diameter of piping: ¼" thread
- Lamp failure control device: visual
- Overall dimensions of assembled unit (L x W x H): 935 × 64 × 109 mm
- Approximate weight: 4.3 kg
Feed water requirements
- Temperature of the treated water: +4...+30 °С
- Turbidity: 0.58 mg/L
- Total hardness: 125 ppm
- Iron: 0.3 ppm
- Manganese: 0.05 ppm
- Hydrogen sulfide: 0.05 ppm
Set of UV disinfection system
- Stainless steel housing assembly
- Quartz sleeve
- UV emitter
- Power supply (electronic ballast)